Install Video:
See attached below attached file written install guide.
New e-step value: 429.9
Additional Notes:
- We do recommenced doing a PID auto tune to most common temperature (PID Auto Tune Guide)
- You will need to re-level your bed or updated your z-off set if you're using a BL Touch/CR Touch, the breakout cable for bl touch/cr touch is not included, you would need to run these cable back to mainboard.
- Plug in your heater, as some batches have heater unplug from breakout boards.