Install Guide for CR Touch Ender 3 v2
Creality Official Firmware: https://www.creality.com/download/
Community Firmware: [Please always double check firmware is correct for your mainboard]
FAQ:
Q: Probe off-set seem to change between prints.
A: In your GCODE, we suggest you home your printer once you bed has heated up to temperature so the probe off-set will be same between each print, as temperature of bed could affect the probe-set value. Similar you should only start bed leveling after bed has heated.
Install Video:
Setup CR Touch Z off-set
Another Beginner Video to Setup Z off-set
Z-Probe Wizard: (8:28-9:00)
Advance Guide: (Custom Wiring)
Credit: https://www.reddit.com/r/BIGTREETECH/comments/pjrkj2/crtouch_wiring_for_btt_skr_v14_and_skr_v2/ (https://www.reddit.com/user/Hickinsauce/)
Note: Our tech support team have verify the wiring is correct on our SKR1.4 and SKR2 and SKR E3 V2.0
Cable | Creality v4.2.2 | SKR 1.4 | SKR 2 |
---|---|---|---|
WHT | G | GND | GND |
BLK | V | NPWR | +5V |
YEL | IN | 2.0 | PE5 |
RED | G | GND | GND |
BLU | OUT | 0.10 | PE4 |
Please always verify pin out from probe, not base off colour wiring as stock cable loom from Creality may change and colour sequence may be flip or different.