How to replace Filament First Stage Feeder for CFS

Created by DREMC STORE, Modified on Wed, 4 Mar at 10:00 PM by DREMC STORE

The first stage feeder in the Creality Filament System (CFS) is a motorised component responsible for automatically feeding filament from the spool to the printer's extruder and retracting it during filament changes . If you encounter clicking noises, failure to load filament, or error messages related to filament feed, the first stage feeder may need replacement . This guide provides step-by-step instructions for safely removing the old feeder unit and installing a new genuine Creality replacement part for your K2 Plus CFS.


TABLE OF CONTENTS


Spare Part: 

Replacement First Stage for CFS


Install Video:

Written Guide:

Source: https://wiki.creality.com/en/cfs/filament-inlet-of-cfs


Note: Ensure CFS is powered off, and filament unloaded and removed from each channel. 


1 Unplug four PTFE tubes

 

 

Remove four screws

 

 

2 Pull out the entire filament inlet

 

Place the entire CFS box upright, manually pull out the entire filament inlet

 

 

 

 3 Unplug the cable

 

Remove the cable cover, unplug the cable from the motor adapter board

 

 

 

 4 Remove the entire filament inlet

 

 

 

5 Remove two screws & unplug the cable

Locate the filament inlet that needs to be replaced, unscrew the fixing screws, and remove two cable wires.

 

 

 

6 Remove the filament inlet that needs to be replaced

Remove the filament inlet to be replaced along the direction of the PTFE tube.

 